2026-03-18T18:43:35.434Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-18T18:43:35.449Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-03-18T18:43:35.449Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-03-18T18:43:35.449Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-18T18:43:35.449Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-03-18T18:43:35.457Z|00006|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.4 2026-03-18T18:43:42.135Z|00007|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-03-18T18:43:42.136Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-18T18:43:42.136Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-18T18:43:42.136Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-18T18:43:42.136Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-18T18:43:42.136Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-18T18:43:42.136Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-18T18:43:42.137Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-18T18:43:42.137Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-18T18:43:42.137Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-18T18:43:42.137Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-18T18:43:42.137Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-18T18:43:42.137Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-18T18:43:42.137Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-18T18:43:42.137Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-18T18:43:42.137Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-18T18:43:42.137Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-18T18:43:42.137Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-18T18:43:42.137Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-18T18:43:42.137Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-18T18:43:42.138Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-18T18:43:42.138Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-18T18:43:42.138Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-18T18:43:42.138Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 16, setting n-revalidator-threads to 5 2026-03-18T18:43:42.138Z|00031|ofproto_dpif_upcall|INFO|Starting 21 threads 2026-03-18T18:43:42.273Z|00032|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-03-18T18:43:42.273Z|00033|bridge|INFO|bridge br-int: using datapath ID 0000c655e5872aae 2026-03-18T18:43:42.273Z|00034|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-03-18T18:43:45.779Z|00035|memory|INFO|199040 kB peak resident set size after 10.3 seconds 2026-03-18T18:43:45.779Z|00036|memory|INFO|handlers:16 idl-cells-Open_vSwitch:101 ports:1 revalidators:5 rules:4 2026-03-18T18:54:38.938Z|00037|bridge|INFO|bridge br-int: deleted interface br-int on port 65534 2026-03-18T18:54:40.177Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-18T18:54:40.187Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-03-18T18:54:40.187Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-03-18T18:54:40.187Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-18T18:54:40.187Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-03-18T18:54:40.196Z|00006|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-18T18:54:40.196Z|00007|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-18T18:54:40.196Z|00008|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-18T18:54:40.196Z|00009|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-18T18:54:40.197Z|00010|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-18T18:54:40.197Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-18T18:54:40.197Z|00012|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-18T18:54:40.197Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-18T18:54:40.197Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-18T18:54:40.197Z|00015|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-18T18:54:40.197Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-18T18:54:40.197Z|00017|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-18T18:54:40.197Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-18T18:54:40.197Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-18T18:54:40.197Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-18T18:54:40.197Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-18T18:54:40.197Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-18T18:54:40.197Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-18T18:54:40.197Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-18T18:54:40.197Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-18T18:54:40.197Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-18T18:54:40.197Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-18T18:54:40.198Z|00028|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 16, setting n-revalidator-threads to 5 2026-03-18T18:54:40.198Z|00029|ofproto_dpif_upcall|INFO|Starting 21 threads 2026-03-18T18:54:40.230Z|00001|fatal_signal(handler1)|WARN|terminating with signal 15 (Terminated) 2026-03-18T18:54:40.351Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-18T18:54:40.361Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-03-18T18:54:40.361Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-03-18T18:54:40.361Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-18T18:54:40.361Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-03-18T18:54:40.370Z|00006|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-18T18:54:40.370Z|00007|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-18T18:54:40.370Z|00008|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-18T18:54:40.370Z|00009|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-18T18:54:40.370Z|00010|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-18T18:54:40.370Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-18T18:54:40.370Z|00012|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-18T18:54:40.370Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-18T18:54:40.371Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-18T18:54:40.371Z|00015|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-18T18:54:40.371Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-18T18:54:40.371Z|00017|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-18T18:54:40.371Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-18T18:54:40.371Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-18T18:54:40.371Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-18T18:54:40.371Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-18T18:54:40.371Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-18T18:54:40.371Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-18T18:54:40.371Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-18T18:54:40.371Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-18T18:54:40.371Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-18T18:54:40.371Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-18T18:54:40.371Z|00028|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 16, setting n-revalidator-threads to 5 2026-03-18T18:54:40.371Z|00029|ofproto_dpif_upcall|INFO|Starting 21 threads 2026-03-18T18:54:40.493Z|00030|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-03-18T18:54:40.493Z|00031|bridge|INFO|bridge br-int: using datapath ID 0000c655e5872aae 2026-03-18T18:54:40.493Z|00032|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-03-18T18:54:40.546Z|00033|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.4 2026-03-18T18:54:41.030Z|00034|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-03-18T18:54:41.031Z|00035|bridge|INFO|bridge br-ex: using datapath ID 000072b2d1469045 2026-03-18T18:54:41.031Z|00036|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-03-18T18:54:44.325Z|00037|connmgr|INFO|br-int<->unix#1: 18 flow_mods in the last 0 s (17 adds, 1 deletes) 2026-03-18T18:54:50.562Z|00038|memory|INFO|199664 kB peak resident set size after 10.2 seconds 2026-03-18T18:54:50.562Z|00039|memory|INFO|handlers:16 idl-cells-Open_vSwitch:199 ofconns:4 ports:2 revalidators:5 rules:26 2026-03-18T18:54:54.558Z|00040|connmgr|INFO|br-int<->unix#5: 18 flow_mods 10 s ago (17 adds, 1 deletes) 2026-03-18T18:55:18.583Z|00041|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-f1416723-10e3-4bad-b48b-3ec0c520341a on port 1 2026-03-18T18:55:18.584Z|00042|bridge|INFO|bridge br-ex: added interface patch-provnet-f1416723-10e3-4bad-b48b-3ec0c520341a-to-br-int on port 1 2026-03-18T18:55:54.558Z|00043|connmgr|INFO|br-int<->unix#5: 554 flow_mods in the 5 s starting 35 s ago (539 adds, 8 deletes, 7 modifications)