2026-03-03T14:13:22.878Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-03T14:13:22.887Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-03-03T14:13:22.887Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-03-03T14:13:22.887Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-03T14:13:22.887Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-03-03T14:13:22.895Z|00006|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.4 2026-03-03T14:13:28.022Z|00007|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-03-03T14:13:28.023Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-03T14:13:28.023Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-03T14:13:28.023Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-03T14:13:28.023Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-03T14:13:28.023Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-03T14:13:28.023Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-03T14:13:28.023Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-03T14:13:28.023Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-03T14:13:28.023Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-03T14:13:28.023Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-03T14:13:28.023Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-03T14:13:28.023Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-03T14:13:28.023Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-03T14:13:28.024Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-03T14:13:28.024Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-03T14:13:28.024Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-03T14:13:28.024Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-03T14:13:28.024Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-03T14:13:28.024Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-03T14:13:28.024Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-03T14:13:28.024Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-03T14:13:28.024Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-03T14:13:28.025Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 16, setting n-revalidator-threads to 5 2026-03-03T14:13:28.025Z|00031|ofproto_dpif_upcall|INFO|Starting 21 threads 2026-03-03T14:13:28.177Z|00032|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-03-03T14:13:28.177Z|00033|bridge|INFO|bridge br-int: using datapath ID 0000dab60bed72dd 2026-03-03T14:13:28.177Z|00034|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-03-03T14:13:33.185Z|00035|memory|INFO|199280 kB peak resident set size after 10.3 seconds 2026-03-03T14:13:33.185Z|00036|memory|INFO|handlers:16 idl-cells-Open_vSwitch:101 ports:1 revalidators:5 rules:4 2026-03-03T14:25:15.366Z|00037|bridge|INFO|bridge br-int: deleted interface br-int on port 65534 2026-03-03T14:25:16.578Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-03T14:25:16.586Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-03-03T14:25:16.586Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-03-03T14:25:16.586Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-03T14:25:16.586Z|00005|fatal_signal|WARN|terminating with signal 15 (Terminated) 2026-03-03T14:25:16.729Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2026-03-03T14:25:16.739Z|00002|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-03-03T14:25:16.739Z|00003|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-03-03T14:25:16.739Z|00004|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2026-03-03T14:25:16.739Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2026-03-03T14:25:16.748Z|00006|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-03-03T14:25:16.748Z|00007|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-03-03T14:25:16.748Z|00008|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-03-03T14:25:16.748Z|00009|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-03-03T14:25:16.748Z|00010|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-03-03T14:25:16.748Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-03-03T14:25:16.749Z|00012|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-03-03T14:25:16.749Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-03-03T14:25:16.749Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-03-03T14:25:16.749Z|00015|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2026-03-03T14:25:16.749Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-03-03T14:25:16.749Z|00017|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-03-03T14:25:16.749Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-03-03T14:25:16.749Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-03-03T14:25:16.749Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-03-03T14:25:16.749Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-03-03T14:25:16.749Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-03-03T14:25:16.749Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-03-03T14:25:16.749Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-03-03T14:25:16.749Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-03-03T14:25:16.749Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-03-03T14:25:16.749Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-03-03T14:25:16.750Z|00028|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 16, setting n-revalidator-threads to 5 2026-03-03T14:25:16.750Z|00029|ofproto_dpif_upcall|INFO|Starting 21 threads 2026-03-03T14:25:16.866Z|00030|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-03-03T14:25:16.866Z|00031|bridge|INFO|bridge br-int: using datapath ID 0000dab60bed72dd 2026-03-03T14:25:16.866Z|00032|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-03-03T14:25:16.867Z|00033|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.4 2026-03-03T14:25:17.328Z|00034|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-03-03T14:25:17.328Z|00035|bridge|INFO|bridge br-ex: using datapath ID 00005222a3242e40 2026-03-03T14:25:17.328Z|00036|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-03-03T14:25:20.591Z|00037|connmgr|INFO|br-int<->unix#1: 18 flow_mods in the last 0 s (17 adds, 1 deletes) 2026-03-03T14:25:26.822Z|00038|memory|INFO|199688 kB peak resident set size after 10.1 seconds 2026-03-03T14:25:26.822Z|00039|memory|INFO|handlers:16 idl-cells-Open_vSwitch:199 ofconns:4 ports:2 revalidators:5 rules:26 2026-03-03T14:25:30.812Z|00040|connmgr|INFO|br-int<->unix#5: 18 flow_mods 10 s ago (17 adds, 1 deletes) 2026-03-03T14:25:55.777Z|00041|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-a24e709a-bf8a-4a2b-acc8-ef5a45cd7df2 on port 1 2026-03-03T14:25:55.777Z|00042|bridge|INFO|bridge br-ex: added interface patch-provnet-a24e709a-bf8a-4a2b-acc8-ef5a45cd7df2-to-br-int on port 1 2026-03-03T14:26:30.812Z|00043|connmgr|INFO|br-int<->unix#5: 554 flow_mods in the 4 s starting 35 s ago (539 adds, 8 deletes, 7 modifications)