+ COMMAND=start + OVS_SOCKET=/run/openvswitch/db.sock + OVS_PID=/run/openvswitch/ovs-vswitchd.pid + start + t=0 + '[' '!' -e /run/openvswitch/db.sock ']' + ovs-vsctl --db=unix:/run/openvswitch/db.sock --no-wait show aea620f2-7d42-4be8-9920-3b99ecc86b27 + exec ovsinit -- /usr/sbin/ovs-vswitchd unix:/run/openvswitch/db.sock -vconsole:emer -vconsole:err -vconsole:info --pidfile=/run/openvswitch/ovs-vswitchd.pid --user=openvswitch:openvswitch --mlockall time=2026-09-19T17:34:38.976Z level=INFO msg="no existing process found" binary=ovs-vswitchd time=2026-09-19T17:34:38.976Z level=INFO msg="claimed succession" binary=ovs-vswitchd pod=openvswitch-hn6cb time=2026-09-19T17:34:38.976Z level=INFO msg="starting process" binary=ovs-vswitchd 2026-09-19T17:34:39Z|00001|ovs_numa|INFO|Discovered 16 CPU cores on NUMA node 0 2026-09-19T17:34:39Z|00002|ovs_numa|INFO|Discovered 1 NUMA nodes and 16 CPU cores 2026-09-19T17:34:39Z|00003|reconnect|INFO|unix:/run/openvswitch/db.sock: connecting... 2026-09-19T17:34:39Z|00004|reconnect|INFO|unix:/run/openvswitch/db.sock: connected 2026-09-19T17:34:39Z|00005|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2026-09-19T17:34:39Z|00006|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.3.7 2026-09-19T17:34:49Z|00007|memory|INFO|317456 kB peak resident set size after 11.0 seconds 2026-09-19T17:34:49Z|00008|memory|INFO|idl-cells-Open_vSwitch:17 2026-09-19T17:41:02Z|00009|dpif_netlink|INFO|Datapath dispatch mode: per-cpu 2026-09-19T17:41:02Z|00010|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2026-09-19T17:41:02Z|00011|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2026-09-19T17:41:02Z|00012|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2026-09-19T17:41:02Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2026-09-19T17:41:02Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2026-09-19T17:41:02Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2026-09-19T17:41:02Z|00016|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2026-09-19T17:41:02Z|00017|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2026-09-19T17:41:02Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2026-09-19T17:41:02Z|00019|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 0 2026-09-19T17:41:02Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2026-09-19T17:41:02Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2026-09-19T17:41:02Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2026-09-19T17:41:02Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2026-09-19T17:41:02Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2026-09-19T17:41:02Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2026-09-19T17:41:02Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2026-09-19T17:41:02Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2026-09-19T17:41:02Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2026-09-19T17:41:02Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2026-09-19T17:41:02Z|00030|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2026-09-19T17:41:02Z|00031|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2026-09-19T17:41:02Z|00032|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 16, setting n-revalidator-threads to 5 2026-09-19T17:41:02Z|00033|ofproto_dpif_upcall|INFO|Starting 21 threads 2026-09-19T17:41:02Z|00034|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2026-09-19T17:41:02Z|00035|bridge|INFO|bridge br-ex: using datapath ID 00000e4d8c11e840 2026-09-19T17:41:02Z|00036|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2026-09-19T17:41:03Z|00037|bridge|INFO|bridge br-int: added interface br-int on port 65534 2026-09-19T17:41:03Z|00038|bridge|INFO|bridge br-int: using datapath ID 0000d63ef14fe1d2 2026-09-19T17:41:03Z|00039|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2026-09-19T17:41:07Z|00040|memory|INFO|peak resident set size grew 57% in last 377.7 seconds, from 317456 kB to 498316 kB 2026-09-19T17:41:07Z|00041|memory|INFO|handlers:16 idl-cells-Open_vSwitch:186 ofconns:4 ports:2 revalidators:5 rules:26 2026-09-19T17:41:13Z|00042|connmgr|INFO|br-int<->unix#15: 18 flow_mods 10 s ago (17 adds, 1 deletes) 2026-09-19T17:52:27Z|00043|bridge|INFO|bridge br-int: added interface o-hm0 on port 1 2026-09-19T17:52:29Z|00044|bridge|INFO|bridge br-int: added interface tapfad3fe99-e0 on port 2 2026-09-19T17:52:37Z|00045|connmgr|INFO|br-int<->unix#15: 267 flow_mods in the 2 s starting 10 s ago (266 adds, 1 deletes) 2026-09-19T18:03:18Z|00046|bridge|INFO|bridge br-int: added interface tap684d23fe-c0 on port 3 2026-09-19T18:03:28Z|00047|connmgr|INFO|br-int<->unix#15: 145 flow_mods in the 1 s starting 10 s ago (141 adds, 2 deletes, 2 modifications) 2026-09-19T18:21:21Z|00048|bridge|INFO|bridge br-ex: added interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 1 2026-09-19T18:21:21Z|00049|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 4 2026-09-19T18:21:31Z|00050|connmgr|INFO|br-int<->unix#15: 1224 flow_mods in the 9 s starting 10 s ago (1192 adds, 22 deletes, 10 modifications) 2026-09-19T18:21:53Z|00051|bridge|INFO|bridge br-ex: deleted interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 1 2026-09-19T18:21:53Z|00052|bridge|INFO|bridge br-int: deleted interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 4 2026-09-19T18:21:58Z|00053|bridge|INFO|bridge br-ex: added interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 2 2026-09-19T18:21:58Z|00054|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 5 2026-09-19T18:22:20Z|00055|bridge|INFO|bridge br-ex: deleted interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 2 2026-09-19T18:22:20Z|00056|bridge|INFO|bridge br-int: deleted interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 5 2026-09-19T18:22:31Z|00057|connmgr|INFO|br-int<->unix#15: 6308 flow_mods in the 47 s starting 58 s ago (2564 adds, 3728 deletes, 16 modifications) 2026-09-19T18:23:01Z|00058|bridge|INFO|bridge br-ex: added interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 3 2026-09-19T18:23:01Z|00059|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 6 2026-09-19T18:23:21Z|00060|bridge|INFO|bridge br-ex: deleted interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 3 2026-09-19T18:23:21Z|00061|bridge|INFO|bridge br-int: deleted interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 6 2026-09-19T18:23:28Z|00062|bridge|INFO|bridge br-ex: added interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 4 2026-09-19T18:23:28Z|00063|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 7 2026-09-19T18:23:31Z|00064|connmgr|INFO|br-int<->unix#15: 1720 flow_mods in the 28 s starting 29 s ago (1100 adds, 612 deletes, 8 modifications) 2026-09-19T18:24:00Z|00065|bridge|INFO|bridge br-ex: deleted interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 4 2026-09-19T18:24:00Z|00066|bridge|INFO|bridge br-int: deleted interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 7 2026-09-19T18:24:31Z|00067|connmgr|INFO|br-int<->unix#15: 1423 flow_mods in the 25 s starting 56 s ago (466 adds, 954 deletes, 3 modifications) 2026-09-19T18:24:38Z|00068|bridge|INFO|bridge br-ex: added interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 5 2026-09-19T18:24:38Z|00069|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 8 2026-09-19T18:24:55Z|00070|bridge|INFO|bridge br-ex: deleted interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 5 2026-09-19T18:24:55Z|00071|bridge|INFO|bridge br-int: deleted interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 8 2026-09-19T18:25:09Z|00072|bridge|INFO|bridge br-ex: added interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 6 2026-09-19T18:25:09Z|00073|bridge|INFO|bridge br-int: added interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 9 2026-09-19T18:25:31Z|00074|connmgr|INFO|br-int<->unix#15: 2354 flow_mods in the last 52 s (1544 adds, 802 deletes, 8 modifications) 2026-09-19T18:25:32Z|00075|bridge|INFO|bridge br-ex: deleted interface patch-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4-to-br-int on port 6 2026-09-19T18:25:32Z|00076|bridge|INFO|bridge br-int: deleted interface patch-br-int-to-provnet-8ae0418c-3ea2-4790-90db-b497cb2a18a4 on port 9 2026-09-19T18:26:31Z|00077|connmgr|INFO|br-int<->unix#15: 748 flow_mods in the 1 s starting 59 s ago (3 adds, 745 deletes)